Flow curve generator
Engineering data. Publication-ready output.
Shading, engineering notes, and the watermark travel with your export.
ENGINEERING 2 TEST CALCULATORALL IN ONE CALCULATOR
Compare pump heads, total flow, pressure, gearbox and motor requirements.
Required flow is the combined delivery. Identical parallel heads add flow; pressure does not multiply. SLA: up to 6 heads. ATP: up to 8 heads.
Above 500 cP, only EV configurations are eligible. Gearbox choices must have a matching source flow curve.
Offline snapshot of the public CheckPoint pump calculator catalog, 11 September 2026, supplemented by the cited CheckPoint datasheets. Capacity is linearly interpolated within each published curve; it is never extrapolated.
Results are candidates, conditional on the listed supply or speed/reducer configuration and head-material rating. Minimum flow uses the catalog floor, multiplied by the same head-count factor as flow. Head-count limits follow the supplied configuration guidance. Multi-head flows assume identical heads at the same duty and speed; drive loading needs separate confirmation unless a matching motor result is shown. No flow correction is made for viscosity, gas, chemical compatibility, relief settings, suction conditions, or application margin.
Reference calculator (online)Loading local catalog…
MOTOR SIZING
Updated SLA charts and source-specific motor sizing.
Updated Adam charts, dated 1 June 2026. Select the complete pump arrangement and discharge pressure.
Chart basis: 1-inch stroke and the stated 5% safety factor. Motor power is taken directly from the selected chart; it is not scaled to other speeds, stroke lengths, or mixed head duties.
UPDATED SLA CHART RESULT
Your duty matches a published pressure column. The kW result is an HP conversion, not a separate IEC motor selection.
Source cell: 'HP Charts 1-2 Head(Adam)'!F26
SLA Motor Power Charts RevA 20200302BG Unlocked.xlsm. Uses the updated HP Charts 1–2, 3–4 and 5–6 Head(Adam) tabs, and only the 9:1 and 15:1 tables at 1450 or 1750 rpm.
Select the first pressure column at or above the duty. Blank cells and pressures above the chart’s row limit do not produce a motor selection. No interpolation or extrapolation is used. kW = HP × 0.7456999.
The head groups follow the worksheet names and validity notes. For two heads with different duties, the source says to use the higher motor requirement. Different simultaneous duties across larger multi-head arrangements need a separate review.